Out
Reflects sunlight outdoors
Reflects sunlight outdoors
Out is an extremely durable, effective collection of exterior screens - woven with coated fiberglass yarns - making these screens ideal for outdoor use. Copaco offers a wide range of fabric and color options that ensure a perfect fit. Two new lines, made with the innovative Block fabrics, Lunar and Solar, provide perfectly blocking & transparency. Out screens are a decorative feature of countless home and offices around the world, giving energy savings and light transmission a new dimension.
Ecrano - white | grey
 
 
openness
factor
2%
product_front
Front
product_back
Back
Widths
This product is only made to order. Please contact us for more information.
Technical info
General
 
 
Composition
Glassfibre 42% - PVC 58%
Openness factor
NBN EN 410
2.00%
Weight
NF EN 12127
650.00 g/m²
Thickness
ISO 5084
0.90 mm
Density
ISO 7211/2
Warp18.00 yarn/cm
Weft21.00 yarn/cm
Color fastness to artificial light
ISO 105 B02
>7
Color fastness to artificial weathering
ISO 105 B04
>7
Air permeability
ISO 9237
1 930.00l/m²/s
Roll length
30 m
Cleaning
With soapy water
Confection
By heat, high frequency or ultrasonic welding
Fire classification
 
Europe
UNE-EN 13501-1:2007
C-s3, d0
France
NF P92-503
M1
Italy
UNI 9177
Class 1
Germany
DIN 4102
B1
UK
BS 5867
C
USA
NFPA 701
FR
Tear strength
ISO 4674-1 methode 2
 
 
Original
Warp6.90 daN
Weft6.50 daN
After climatic chamber -30°C
Warp6.60 daN
Weft6.80 daN
After climatic chamber +70°C
Warp6.50 daN
Weft6.50 daN
Elongation up to break
ISO 1421
 
 
Original
Warp4.10 %
Weft4.00 %
After colour fastness to artificial weathering
Warp4.00 %
Weft3.60 %
After climatic chamber -30°C
Warp4.20 %
Weft4.20 %
After climatic chamber +70°C
Warp4.40 %
Weft4.30 %
Breaking strength
ISO 1421
 
 
Original
Warp360.00 daN/5cm
Weft300.00 daN/5cm
After colour fastness to artificial weathering
Warp330.00 daN/5cm
Weft250.00 daN/5cm
After climatic chamber -30°C
Warp355.00 daN/5cm
Weft318.00 daN/5cm
After climatic chamber +70°C
Warp355.00 daN/5cm
Weft310.00 daN/5cm
Front - Interior
 
 
Visual properties
Tv = Visual light transmittance
5.50%
Tuv = UV transmittance
3.40%
Solar energetic properties
As = Solar absorptance
75.30%
Rs = Solar reflectance
19.00%
Ts = Solar transmittance
5.70%
Fabric + glazing: G-factor
 
G
Te
Qi
SC
Glazing A
G 0.56
Te 0.05
Qi 0.51
SC 0.65
Glazing B
G 0.57
Te 0.04
Qi 0.53
SC 0.75
Glazing C
G 0.50
Te 0.03
Qi 0.47
SC 0.84
Glazing D
G 0.29
Te 0.02
Qi 0.27
SC 0.90
  • G = Total solar energy transmittance
  • Te = Direct solar transmittance
  • Qi = Secondary heat transfer factor
  • SC = Shading coefficient
Visual comfort
Normal solar transmittance
Class 4
Very good effect
Glare control
Class 2
Moderate effect
Privacy night
Class 2
Moderate effect
Visual contact with the outside
Class 2
Moderate effect
Daylight utilisation
Class 1
Little effect
Thermal comfort G-factor = Total solar energy transmittance
Glazing A
Class 0
Very little effect
Glazing B
Class 0
Very little effect
Glazing C
Class 1
Little effect
Glazing D
Class 2
Moderate effect
Thermal comfort Qi-factor = Secondary heat transfer factor
Glazing A
Class 0
Very little effect
Glazing B
Class 0
Very little effect
Glazing C
Class 0
Very little effect
Glazing D
Class 1
Little effect
  • Class 0 = Very little effect
  • Class 1 = Little effect
  • Class 2 = Moderate effect
  • Class 3 = Good effect
  • Class 4 = Very good effect
Back - Interior
 
 
Visual properties
Tv = Visual light transmittance
5.50%
Tuv = UV transmittance
3.40%
Solar energetic properties
As = Solar absorptance
43.70%
Rs = Solar reflectance
50.60%
Ts = Solar transmittance
5.70%
Fabric + glazing: G-factor
 
G
Te
Qi
SC
Glazing A
G 0.39
Te 0.05
Qi 0.34
SC 0.46
Glazing B
G 0.42
Te 0.04
Qi 0.38
SC 0.55
Glazing C
G 0.40
Te 0.03
Qi 0.37
SC 0.67
Glazing D
G 0.26
Te 0.02
Qi 0.24
SC 0.81
  • G = Total solar energy transmittance
  • Te = Direct solar transmittance
  • Qi = Secondary heat transfer factor
  • SC = Shading coefficient
Visual comfort
Normal solar transmittance
Class 4
Very good effect
Glare control
Class 2
Moderate effect
Privacy night
Class 2
Moderate effect
Visual contact with the outside
Class 2
Moderate effect
Daylight utilisation
Class 1
Little effect
Thermal comfort G-factor = Total solar energy transmittance
Glazing A
Class 1
Little effect
Glazing B
Class 1
Little effect
Glazing C
Class 1
Little effect
Glazing D
Class 2
Moderate effect
Thermal comfort Qi-factor = Secondary heat transfer factor
Glazing A
Class 0
Very little effect
Glazing B
Class 0
Very little effect
Glazing C
Class 0
Very little effect
Glazing D
Class 1
Little effect
  • Class 0 = Very little effect
  • Class 1 = Little effect
  • Class 2 = Moderate effect
  • Class 3 = Good effect
  • Class 4 = Very good effect
Front - Exterior
 
 
Visual properties
Tv = Visual light transmittance
5.50%
Tuv = UV transmittance
3.40%
Solar energetic properties
As = Solar absorptance
75.30%
Rs = Solar reflectance
19.00%
Ts = Solar transmittance
5.70%
Fabric + glazing: G-factor
 
G
Te
Qi
SC
Glazing A
G 0.16
Te 0.05
Qi 0.11
SC 0.19
Glazing B
G 0.12
Te 0.04
Qi 0.08
SC 0.16
Glazing C
G 0.08
Te 0.03
Qi 0.04
SC 0.13
Glazing D
G 0.06
Te 0.02
Qi 0.04
SC 0.19
  • G = Total solar energy transmittance
  • Te = Direct solar transmittance
  • Qi = Secondary heat transfer factor
  • SC = Shading coefficient
Thermal comfort G-factor = Total solar energy transmittance
Glazing A
Class 2
Moderate effect
Glazing B
Class 3
Good effect
Glazing C
Class 4
Very good effect
Glazing D
Class 4
Very good effect
Thermal comfort Qi-factor = Secondary heat transfer factor
Glazing A
Class 2
Moderate effect
Glazing B
Class 3
Good effect
Glazing C
Class 3
Good effect
Glazing D
Class 3
Good effect
  • Class 0 = Very little effect
  • Class 1 = Little effect
  • Class 2 = Moderate effect
  • Class 3 = Good effect
  • Class 4 = Very good effect
Back - Exterior
 
 
Visual properties
Tv = Visual light transmittance
5.50%
Tuv = UV transmittance
3.40%
Solar energetic properties
As = Solar absorptance
43.70%
Rs = Solar reflectance
50.60%
Ts = Solar transmittance
5.70%
Fabric + glazing: G-factor
 
G
Te
Qi
SC
Glazing A
G 0.11
Te 0.05
Qi 0.07
SC 0.13
Glazing B
G 0.09
Te 0.04
Qi 0.05
SC 0.12
Glazing C
G 0.06
Te 0.03
Qi 0.03
SC 0.10
Glazing D
G 0.05
Te 0.02
Qi 0.03
SC 0.14
  • G = Total solar energy transmittance
  • Te = Direct solar transmittance
  • Qi = Secondary heat transfer factor
  • SC = Shading coefficient
Thermal comfort G-factor = Total solar energy transmittance
Glazing A
Class 3
Good effect
Glazing B
Class 4
Very good effect
Glazing C
Class 4
Very good effect
Glazing D
Class 4
Very good effect
Thermal comfort Qi-factor = Secondary heat transfer factor
Glazing A
Class 3
Good effect
Glazing B
Class 3
Good effect
Glazing C
Class 3
Good effect
Glazing D
Class 4
Very good effect
  • Class 0 = Very little effect
  • Class 1 = Little effect
  • Class 2 = Moderate effect
  • Class 3 = Good effect
  • Class 4 = Very good effect
5 years warrantyIndoor comfortEasy maintenanceEnergy savingFlame retardantLead freePrintableReach compliant
Get in touch
Contact us